PCB relay with forcibly guided contacts |
| - |
Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation diagonally between left and right contact side (leakage and creeping distances > 5,5mm) |
| - |
EN 50205 type B |
| - |
2 CO contacts |
| - |
Mean coil power ca. 1 W |
| - |
Holding power 0.31W |
|
|
 |
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance in Ohm at 20 °C |
Tolerance
in % |
| 5 |
3,75 |
> 0,5 |
181,8 |
27,5 |
± 10 |
| 6 |
4,5 |
> 0,6 |
166,6 |
36 |
± 10 |
| 12 |
9,0 |
> 1,2 |
85,7 |
140 |
± 10 |
| 18 |
13,5 |
> 1,8 |
66,6 |
270 |
± 10 |
| 24 |
18,0 |
> 2,4 |
33,3 |
720 |
± 10 |
| 48 |
36,0 |
> 4,8 |
20,8 |
2‘300 |
± 10 |
| 60 |
45,0 |
> 6,0 |
13,6 |
4‘400 |
± 13 |
| 110 |
82,5 |
> 11,0 |
11,0 |
10‘000 |
± 15 |
|
| |
|
|
|
| |
Ordering example
|
|
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|