PCB relay with forcibly guided contacts |
| - |
Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) |
| - |
EN 50205 type A |
| - |
Contact mounting: SIM112 1NO/1NC |
| - |
Small external dimensions |
| - |
Mean coil power ca. 0,5W |
| - |
Holding power 0.15W |
|
|
 |
|
|
|
|
| |
|
| |
Standard coils for direct current (other voltages on request)
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 5 |
3,5 |
> 0,5 |
111,0 |
45 |
± 10 |
| 6 |
4,2 |
> 0,6 |
85,7 |
70 |
± 10 |
| 12 |
8,4 |
> 1,2 |
44,4 |
270 |
± 10 |
| 21 |
14,7 |
> 2,1 |
23,8 |
880 |
± 10 |
| 24 |
16,8 |
> 2,4 |
21,8 |
1‘100 |
± 10 |
| 48 |
33,6 |
> 4,8 |
10,9 |
4‘400 |
± 13 |
| 60 |
42,0 |
> 6,0 |
8,7 |
6‘850 |
± 15 |
| 110 |
77,0 |
> 11,0 |
5,5 |
20‘000 |
± 15 |
|
| |
|
|
|
| |
Ordering example
|
|
|
|
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|