PCB relay with forcibly guided contacts |
| - |
Protective separation between coil and contacts (leakage and creepage distances > 14mm); protective separation between left and right contact side (leakage and creeping distances > 5.5mm) |
| - |
EN 50205 type A |
| - |
Contact mounting: SIM212 2NO/1NC |
| - |
Small external dimensions |
| - |
Mean coil power 0.75W |
| - |
Holding power 0.21W |
|
|
 |
| |
|
|
|
|
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 5 |
3,75 |
> 0,5 |
151,0 |
33 |
± 10 |
| 6 |
4,5 |
> 0,6 |
125,0 |
48 |
± 10 |
| 12 |
9,0 |
> 1,2 |
63,1 |
190 |
± 10 |
| Â 21 |
 15,75 |
> 2,1 |
 35,5 |
 590 |
 ± 10 |
| 24 |
18,0 |
> 2,4 |
30,0 |
800 |
± 10 |
| 48 |
36,0 |
> 4,8 |
15,4 |
3‘100 |
± 10 |
| 60 |
45,0 |
> 6,0 |
12,5 |
4‘800 |
± 13 |
| 110 |
82,5 |
> 11,0 |
6,8 |
16‘000 |
± 15 |
|
| |
|
|
|
| |