PCB relay with forcibly guided contacts |
| - |
Protective separation between coil/control contacts and output contacts (> 8mm) and output contacts in one row (> 8mm) |
| - |
EN 50205 type A |
| - |
Contact mounting:
SIP512
Control contacts 1NO/1NC
Output contacts 4AK
SIP422
Control contacts 2NC
Output contacts 4AK |
| - |
Small external dimensions |
| - |
Mean coil power 1.3W |
| - |
Holding power 0.39W |
| - |
For Railway Applications: EN 50155 |
|
|
|
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
| |
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 6 |
4,2 |
> 0,6 |
218 |
27,5 |
± 10 |
| 12 |
8,4 |
> 1,2 |
109 |
110 |
± 10 |
| 18 |
12,6 |
> 1,8 |
72,5 |
248 |
± 10 |
| 24 |
16,8 |
> 2,4 |
54,5 |
440 |
± 10 |
| 48 |
33,6 |
> 4,8 |
27,2 |
1‘760 |
± 10 |
| 60 |
42,0 |
> 6,0 |
11,8 |
2‘750 |
± 10 |
| 110 |
77,0 |
> 11,0 |
6,8 |
9‘250 |
± 13 |
| 220 |
154,0 |
> 22,0 |
5,9 |
37‘000 |
± 15 |
|
| |
|
|
|
|
|
|
Ordering example
|
|
|
|
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|