PCB relay with forcibly guided contacts |
| - |
Protective separation between coil/control contacts and output contacts (> 8mm) as well as protective separation between the output contacts themselves (> 8mm) |
| - |
EN 50205 type A |
| - |
Double and reinforced insulation between the contacts |
| - |
Contact mounting:
SIR312P: Control contacts 1NO/1NC
Output contacts 2NO
SIR222P: Control contacts 2NC
Output contacts 2NO
|
| - |
Small external dimensions |
| - |
Mean coil power 0,75 W |
|
|

 |
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
|
|
|
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance in Ohm at 20 °C |
Tolerance
in % |
| 5 |
< 3,5 |
> 0,5 |
151,0 |
33 |
± 10 |
| 6 |
< 4,2 |
> 0,6 |
125,0 |
48 |
± 10 |
| 12 |
< 6,3 |
> 0,9 |
63,1 |
190 |
± 10 |
| 24 |
< 8,4 |
> 1,2 |
31,5 |
760 |
± 10 |
| 48 |
< 12,6 |
> 1,8 |
15,7 |
3‘050 |
± 10 |
| 60 |
< 16,8 |
> 2,4 |
12,5 |
4‘800 |
± 10 |
| 110 |
< 33,6 |
> 4,8 |
6,8 |
16‘000 |
± 15 |
|
| |
|
|
|
| |
Ordering example
|
|
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|