PCB relay with forcibly guided contacts |
| - |
Protective separation between coil/control contacts and output contacts (> 10mm) as well as protective separation between the output contacts themselves (> 8mm) |
| - |
EN 50205 type A |
| - |
Contact mounting:
SIR332 3NO/3NC
SIR422 4NO/2NC
SIR512 5NO/1NC |
| - |
Mean coil power ca. 1 W |
| - |
Small external dimensions |
| - |
Mean coil power 0.75W |
| - |
Holding power 0.22W |
| - |
For Railway Applications: EN 50155 |
|
|
 |
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 5 |
3,5 |
> 0,5 |
151,0 |
33 |
± 10 |
| 6 |
4,2 |
> 0,6 |
125 |
48 |
± 10 |
| 12 |
8,4 |
> 1,2 |
63,1 |
190 |
± 10 |
| 18 |
12,6 |
> 1,8 |
41,6 |
432 |
± 10 |
| 24 |
16,8 |
> 2,4 |
31,5 |
760 |
± 10 |
| 48 |
33,6 |
> 4,8 |
15,7 |
3‘050 |
± 10 |
| 60 |
42,0 |
> 6,0 |
12,5 |
4‘800 |
± 13 |
| 110 |
77,0 |
> 11,0 |
6,8 |
16‘000 |
± 15 |
|
| |
|
|
|
| |
Ordering example
|
|
|
|
|
| |
 |
|
|
| |
|
|
|