PCB relay with forcibly guided contacts |
| - |
Protective separation between control and load circuit (leakage and creepage distance > 8mm) |
| - |
EN 50205 type A |
| - |
Double and reinforced insulation between the contacts |
| - |
Contact mounting: SIS212 2NO/1NC |
| - |
Small external dimensions |
| - |
Mean coil power 0.6W |
| - |
Holding power 0.18W |
|
|
|
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
|
|
|
|
| |
|
|
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 5 |
< 3,5 |
> 0,5 |
120,0 |
41,5 |
± 10 |
| 9 |
< 6,3 |
> 0,9 |
66,6 |
135 |
± 10 |
| 12 |
< 8,4 |
> 1,2 |
50,0 |
240 |
± 10 |
| 18 |
< 12,6 |
> 1,8 |
33,3 |
540 |
± 10 |
| 24 |
< 16,8 |
> 2,4 |
25,0 |
960 |
± 10 |
| 48 |
< 33,6 |
> 4,8 |
12,5 |
3‘840 |
± 10 |
| 60 |
< 42,0 |
> 6,0 |
10,0 |
6‘000 |
± 13 |
| 110 |
< 77,0 |
> 11,0 |
5,4 |
20‘150 |
± 15 |
|
| |
|
|
|
| |
Ordering example
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|