PCB relay with forcibly guided contacts |
| - |
Protective separation between control and load circuit (leakage and creepage distance > 8mm) |
| - |
EN 50205 type A |
| - |
Double and reinforced insulation between the contacts |
| - |
Contact mounting: SIS422 4NO/2NC |
| - |
Small external dimensions |
| - |
Mean coil power 0.66W |
| - |
Holding power 0.20W |
| - |
For Railway Applications: EN 50155 |
|
|
 |
| |
|
|
|
| |
Standard coils for direct current (other voltages on request)
|
| |
|
| |
Nominal
voltage VDC |
Min. pick-up
voltage at 20°C |
Drop-out
voltage at 20 °C |
Nominal
current in mA |
Resistance
in Ohm at 20 °C |
Tolerance
in % |
| 5 |
3,5 |
> 0,5 |
133 |
37,5 |
± 10 |
| 9 |
6,3 |
> 0,9 |
73,7 |
122 |
± 10 |
| 12 |
8,4 |
> 1,2 |
55,8 |
215 |
± 10 |
| 18 |
12,6 |
> 1,8 |
37,1 |
485 |
± 10 |
| 24 |
16,8 |
> 2,4 |
29,7 |
860 |
± 10 |
| 48 |
33,6 |
> 4,8 |
13,9 |
3‘450 |
± 10 |
| 60 |
42,0 |
> 6,0 |
11,1 |
5‘400 |
± 13 |
| 110 |
77,0 |
> 11,0 |
6,0 |
18‘300 |
± 15 |
|
| |
|
| |
Ordering example
|
|
|
| |
|
|
|
| |
 |
|
|
| |
|
|
|